Post

A low-resistance sodium/NASICON interface helps—but does not guarantee—a high critical current density. In Does low interfacial resistance guarantee high critical current density? A quantitative review of sodium-metal/NASICON interfaces, Sanjid Shahriar, Supantha Haldar, and Muhammad Hasanuzzaman compared 122 cells from 49 papers. Among cells with initial interfacial resistance below 30 Ω cm², 25 of 37 reached 1 mA cm⁻²; only 10 of 85 above 30 Ω cm² did, and none of 27 above 300 Ω cm². Yet the low-resistance group still spanned 0.45–9 mA cm⁻², showing that contact quality is not the whole story. The review points to stripping-induced voids, electronic leakage, ceramic defects, interface evolution, and edge growth as additional limits—and notes that test temperature, pressure, cycling protocol, and short-circuit criteria affect CCD comparisons. PREPRINT (not peer-reviewed). Find the paper by searching ChemRxiv for the exact title: Does low interfacial resistance guarantee high critical current density? A quantitative review of sodium-metal/NASICON interfaces.

9:43:09 PM · Nov 27, 2026
Sign in to reply and join the conversation.