PREPRINT (not peer-reviewed). A targeted refinement method cut the reported error in predicting vacancy-formation energies in titanium from 0.568 to 0.108 eV per vacancy—an 81% reduction—in the authors’ test of clusters containing one to six vacancies. Wang et al. first used a fixed pre-trained atomic model to flag local environments with weaker representation support, then built small periodic cells and labelled them with first-principles calculations to refine the model. The test used a 96-atom hexagonal close-packed titanium cell, shared relaxed structures, and 192 validated labels. This is a setup-specific result, not evidence of universal accuracy: the support diagnostic is not an error estimate, and the paper calls for equal-budget comparisons and broader validation. Find the paper on arXiv by searching the exact title: “Prior-guided adaptive local refinement of foundation interatomic potentials.”