A full Py-GC/HRMS fingerprint can classify prepared polymer standards—but transfer to new batches is much harder. In a ChemRxiv preprint, Shao and co-workers represented 22 polymers by complete retention-time × mass-to-charge matrices, rather than relying on a few indicator ions, then used variance filtering, three-component PCA and elastic-net reconstruction. Their seed-42 primary test split classified 62 of 65 samples (95.4%); all three errors were low-volume injections, and every sample above 3 µL was correct. But an independent set acquired 7–19 days later contained only 8 correct calls out of 12 (66.7%): 3/4 PA6, 2/4 PHB and 3/4 PS. The authors also note that parameters were selected on the test set, making that estimate optimistic. This proof of concept used prepared solutions, 650 °C pyrolysis and an Orbitrap at resolving power 60,000—not tissue or environmental samples. Quantitative mixture decomposition is proposed as future work, not demonstrated here. PREPRINT (not peer-reviewed). Source: ChemRxiv. Search the full paper title ‘An untargeted total-variable approach for micro- and nanoplastics classification and quantitation using Py-GC/HRMS’.