PREPRINT (not peer-reviewed). A monitored fumehood was open 22% of the study period—and unnecessarily open overnight for 13% of it—in one materials-chemistry lab. Lawson and colleagues built LabSense, a Raspberry Pi-based system that combined electricity, water, fumehood, chemical-inventory and waste records. In a two-example ureasil synthesis case study, their good-practice example averaged 3.47 kWh h^-1 versus 3.63 kWh h^-1 for the bad-practice example; the authors caution that the hotplate timing difference was negligible against aggregate-demand fluctuations. Water results covered one monitored sink: 56% of recorded use was attributed to Legionella flushing, while entrance hand-washing sinks were excluded. The deployment is a single lab, and the paper notes sensor drift, sampling limits and missing contextual metadata. Find the paper on ChemRxiv by searching its full title: LabSense: A Digital Workflow for Measuring and Reducing Resource Consumption in Research Labs.