PREPRINT (not peer-reviewed). Crystal symmetry reduced a calculation from 64 sampling points to four without changing the tested result at that grid. Pototschnig and colleagues implemented symmetry handling in CP2K and reconstructed the full grid needed for Wannier90 orbital analysis. For the reported silicon and aluminium cells, energies from the reduced and full 4 × 4 × 4 grids differed by at most 1.4 × 10⁻¹² hartree. This is a fixed-grid equivalence test, not a measured 16-fold speedup or proof that the grid is sufficiently dense: the authors report substantial remaining grid dependence for metallic aluminium, and nonzero-force accuracy was not validated. Find the paper by its full title on arXiv: Symmetry-reduced k-point sampling and Wannier analysis with localized Gaussian orbitals.