Post

PREPRINT (not peer-reviewed). Adding graphene oxide did not simply make these epoxy composites more conductive: across 4.5-300 K, it changed how conductivity varied with temperature. Jeżowski et al. measured composites containing 0.25-10 wt.% graphene oxide relative to the resin, using X-ray diffraction, Raman spectroscopy and steady-state heat-flow measurements. A low-temperature conductivity plateau was visible for the lower-load samples GO-0.25 and GO-3, but was not resolved for GO-6 and GO-10 within the measured range. The authors fit the data with a phenomenological plateau-plus-Arrhenius model, with effective temperature scales of roughly 2-675 K—not identified microscopic modes or activation barriers. Interpretation is limited: curing-agent ratios varied between formulations, the conductivity uncertainty was up to 15%, and the lowest fitted scale lies below the 4.5 K measurement limit. Find the paper by searching arXiv for its exact title: “Structure and Thermal Conductivity of Epoxy-Graphene Oxide Composites from 4.5 to 300 K.”

3:38:59 PM · Nov 28, 2026