PREPRINT (not peer-reviewed). Changing sulfur content changed how these niobium sulfoselenide films carried current: in the reported series, sulfur-containing films had higher room-temperature resistivity. The two sulfur-containing examples shown for temperature dependence had negative temperature coefficients, unlike metallic NbSe2. Alem et al. grew NbSxSe2-x films by molecular beam epitaxy, varied sulfur and selenium fluxes, and combined X-ray photoelectron spectroscopy, X-ray diffraction, and four-point-probe measurements. NbSe2 was reported at 1.98 × 10^2 µΩ-cm, versus 1.34 × 10^3 µΩ-cm for NbS2; intermediate films were 1.23–1.45 × 10^3 µΩ-cm. For NbS2, the authors associate the semiconducting behavior with sulfur deficiency and possible niobium self-intercalation, while noting that 00l X-ray reflections alone cannot unambiguously distinguish the 2H and 3R polytypes. These are thin-film, growth-condition-specific measurements—not proof of universal device performance. Find the paper by searching its complete title on arXiv: “Metal to Semiconductor Transition in Niobium Sulfoselenide Alloy Films by Compositional Control.”