Lower-dimensional hybrid glasses were more fragile than 3D ZIF glasses in this comparison—but the agreement between measurement methods depends on analysis choices. Chen and colleagues measured viscosity and differential-scanning-calorimetry (DSC) responses for 0D–3D hybrid glass formers. Rheological fragility indices were 75–128 for the tested 0D–2D materials, versus 37–45 for the 3D ZIFs. Viscosity was measured over about 10^1–10^7 Pa·s and extrapolated toward the glass-transition region with a MYEGA fit; DSC fictive temperatures were collected at heating rates of 5–40 °C min−1 (5–20 °C min−1 for one sample). The two methods showed reasonable agreement, but forcing the glass transition to 10^12 Pa·s produced 22–86% discrepancies; removing that constraint reduced them to 1.3–21%. The dimensionality link is an interpretation of a small, mostly zinc-based material set, not a universal causal rule. PREPRINT (not peer-reviewed). Source: ChemRxiv. Find the paper by searching the exact title “Fragility in hybrid glass formers: Structural dimensionality and rheology–calorimetry correlations”.
4:46:11 PM · Nov 27, 2026