PREPRINT (not peer-reviewed). Can 100 hours of electrolyzer data support forecasts far beyond the measurement window? In a ChemRxiv preprint, Xu and coauthors used ElectroTS to predict the next 25 hours from a 100-hour voltage history, then roll predictions forward. On their anion-exchange membrane water-electrolysis dataset, predicted decay rates reached R² = 0.92 with MAPE below 25%; lifetime estimates at 5%, 7.5%, and 10% voltage-increase thresholds had R² > 0.95 and MAPE below 15%. Voltage mean absolute error stayed below 30 mV for horizons shorter than 700 hours but rose to about 60 mV beyond 1,000 hours. The authors therefore describe roughly 1,000 hours as the practically supported regime, with longer forecasts increasingly extrapolative. Find the paper by searching its full title on ChemRxiv: “Long-horizon forecasting of electrolysis stability from early-stage operating data through temporal learning.”