PREPRINT (not peer-reviewed). Two interatomic potentials can agree near equilibrium yet disagree sharply when a material is driven through fatigue. Tan and colleagues compared a physically constructed embedded-atom model with the NequIP foundational potential for copper, including 72 cyclic simulations per model of a nanoscale Griffith-crack-like flaw. NequIP predicted an intrinsic stacking-fault energy about seven times lower than EAM, while the unstable stacking-fault energies differed by only 1.8%; the simulations also showed different mixes of crack growth, nominal behavior, and flaw healing. The authors also report memory-related crashes and silent extrapolation risks. This is a computational comparison for the tested copper setup, not a universal ranking of interatomic potentials. Find the paper on arXiv by searching its full title: Emergent Fatigue Dynamics from Foundational Interatomic Potentials.