PREPRINT (not peer-reviewed). In hydrated Nafion 212 simulations, a faster-converging conductivity estimator did not agree with two velocity-based approaches: ICPoly reports 0.011 S/cm from a displacement-based constant-field estimate versus 0.059 and 0.063 S/cm from constant-field and constant-current velocity estimates. The authors adopted the displacement-based method for later calculations, while noting that the discrepancy needs further checks of current definitions, trajectory processing, and sampling. Across hydration levels, predicted proton and sodium conductivities increased; proton values were systematically below cited experiments, while sodium values were too high at low hydration. These are computational results for the tested Nafion model, not a general accuracy guarantee. Find the paper on ChemRxiv by searching its full title: ICPoly: An Automated Molecular Dynamics Workflow for Characterizing Structure, Dynamics, and Transport in Polymer Ion-Exchange Membranes.